Interrupt Status register for Master, Slave, and Monitor functions.
MSTPENDING | Master Pending. |
RESERVED | Reserved. |
MSTARBLOSS | Master Arbitration Loss flag. |
RESERVED | Reserved. Read value is undefined, only zero should be written. |
MSTSTSTPERR | Master Start/Stop Error flag. |
RESERVED | Reserved. Read value is undefined, only zero should be written. |
SLVPENDING | Slave Pending. |
RESERVED | Reserved. Read value is undefined, only zero should be written. |
SLVNOTSTR | Slave Not Stretching status. |
RESERVED | Reserved. Read value is undefined, only zero should be written. |
SLVDESEL | Slave Deselected flag. |
MONRDY | Monitor Ready. |
MONOV | Monitor Overflow flag. |
RESERVED | Reserved. Read value is undefined, only zero should be written. |
MONIDLE | Monitor Idle flag. |
RESERVED | Reserved. Read value is undefined, only zero should be written. |
EVENTTIMEOUT | Event time-out Interrupt flag. |
SCLTIMEOUT | SCL time-out Interrupt flag. |
RESERVED | Reserved. Read value is undefined, only zero should be written. |